CAN/CAN Gateway CG-ARM7

CAN/CAN Gateway CG-ARM7

is rail mountable CAN/CAN gateway, which transmits CAN signals between subsystems.

Special Features

CAN/CAN Gateway CG-ARM7

  • Connection of CAN subnetworks with differing data rates
  • Filtering and buffering of data traffic
  • Support of 11-bit and 29-bit identifiers
  • Increase of the system extension
  • Powerful Cortex M3 microcontroller with internal CAN controller
  • Rail mountable

 

Description

The rail mountable CAN/CAN gateway CG-ARM7/RMD transmits CAN signals between subsystems. CG-ARM7/RMD allows a flexible design of the wiring topology. Star and tree structures as well as extensive line structures can be realized. Among the available functions are data rate adaption, message filtering as well as identifier conversion between the coupled busses. The restriction of the maximum data rate depending on cable length for single CAN segments can be abolished for the over-all system by use of CG-ARM7/RMD.

CG-ARM7/RMD obtains its potential through the use of a 32 bit microcontroller with 96 MHz clock. High speed processing and low latencies allow the use with high data rates and busloads. Cost efficient series applications are particularly promoted by use of CG-ARM7/RMD.

The configuration of the device functions can take place either through CAN or through the built-in RS232 interface. CG-ARM7/RMD can be deliverd with a customer specific baudrate configuration. Download software for the configuration is available for Windows PCs as well as Linux PCs.

Ordering information

Equipment / Variants

12-20-401-10

CG-ARM7/RMD

Galvanic separation: None

Number of channels: 2 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

0

Technical Data

Layout and Connection

The connection to the CAN busses is achieved via pluggable terminals. Besides the CAN signals the clamps also carry the supply voltage for CG-ARM7.
The following table shows the pin assignment of the internally connected interfaces.

PinNameFunction
1+24 VSupply voltage
2, 3, 6GNDGround
4CAN1_HCAN1 signal line (dominant high)
5CAN1_LCAN1 signal line (dominant low)
7CAN2_HCAN2 signal line (dominant high)
8CAN2_LCAN2 signal line (dominant low)

Limiting Values

ParameterMinimumMaximumUnit
Storage temperature-40+85°C
Operating temperature-20+85°C
Supply voltage-100+35V
Voltage on bus connections-30+30V
Admissible power consumption (at 60 °C)n.s.2000mW

Any (also temporary) stress in excess of the limiting values may cause permanent damage on CG-ARM7 and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.

Nominal Values

ParameterMinimumTypicalMaximumUnit
Current consumption (running idle)n.s.40n.s.mA
Supply voltage102430V

All values, unless otherwise specified, refer to a supply voltage of 24 V and an environmental temperature of 20 °C.

Scope of Delivery

Related Products

CAN/CAN Gateway CG-ARM7/GTI

CAN/CAN Gateway CG-ARM7/D/E

Serial/CAN Gateway SerCAN

Further Information

CAN Gateway vs. Repeater

International Sales

For US/Canada/Mexico sales, please contact: Traquair Data Systems, Inc. (www.traquair.com); sales@traquair.com; Ph: +1 607 266 6000