CAN-Repeater CRep S10I

CAN-Repeater CRep S10I

The compact CAN repeater CRep S10I transmits and amplifies signals transparent to the CAN protocol.

Special Features

CAN-Repeater CRep S10I

  • Protocol transparent CAN repeater
  • 10 CAN channels
  • Low propagation delay
  • Galvanic separation between CAN channels and power supply
  • ISO 11898 compatible bus interface
  • Detach of dominant locked bus segments
  • Rail mountable

Description

The compact CAN repeater CRep S10I transmits and amplifies signals transparent to the CAN protocol. Each of the ten CAN connections has the physical behaviour of a single bus node. CRep S10I permits a flexible design of the network topology and offers special support for star structured networks. Furthermore treestructures and long stub lines are supported. Through the possibility to use the network structure that fits the application best a reduction of installation costs can be reached. The maximum data rate in CAN networks, depending on signal propagation delays, can be increased, if CRep S10I is used to improve the network structure. An increase of the maximum node count in a CAN network can be reached by splitting the network in subnets that are connected by CRep S10I. Each subnet makes the number of CAN nodes possible permitted by the drivers output current. Where CAN signals have to be transmitted over long distances, CRep S10I can be used for signal conditioning. The capability to detach erroneous segments from the rest of the CAN system reduces the impact on the intact bus segments for the most commonly occuring errors. All CAN channels are galvanic separated to each other and to the power supply. The presence of power is indicated by a LED. Each CAN channel is provided with a LED indicating that this channel has originated a CAN message.

Ordering information

Equipment / Variants

12-05-002-10

CRepS10I-05/S24/RMD

Off-period: 500 ns

For baud rate: 500 kB/s

For baud rate: 250 kB/s

Galvanic seperation: Host separated, Channels separated

Numbers of channel: 10 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

12-05-003-10

CRepS10I-10/S24/RMD

Off-period: 1000 ns

For baud rate: 125 kB/s

Galvanic seperation: Host separated, Channels separated

Numbers of channel: 10 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

12-05-004-10

CRepS10I-20/S24/RMD

Off-period: 2000 ns

For baud rate: 50 kB/s

Galvanic seperation: Host separated, Channels separated

Numbers of channel: 10 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

12-05-005-10

CRepS10I-50/S24/RMD

Off-period: 5000 ns

For baud rate: 20 kB/s

Galvanic seperation: Host separated, Channels separated

Numbers of channel: 10 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

12-05-006-10

CRepS10I-100/S24/RMD

Off-period: 10000 ns

For baud rate: 10 kB/s

Galvanic seperation: Host separated, Channels separated

Numbers of channel: 10 Channel

CAN Physics: high speed

Structural shape: Mounting rail

Protocol: CAN

0

Technical Data

Layout and Connection

A CRep S10I device includes 10 CAN segments, wired by terminal blocks with 3 clamps. The power supply of CRep S10I is separately wired by a terminal block with 2 clamps.

Pin Name Function
1 CAN_ H CAN high bus line
2 CAN_ L CAN low bus line
3 GND Ground

The following table shows the terminal assignment of the power connector:

Pin Name Function
1 Power + Positive supply +24V
2 Power – Ground of power supply

The power supply is galvanicly decoupled from the CAN system.

Lim iting Values

Parameter Minimum Maximum Unit
Storage temperature -40 + 80 °C
Operating temperature -20 + 60 °C
Power supply voltage -100 + 35 V
Voltage on signal lines -30 + 30 V
Maximum power dissipation (at 60°C) tbd mW

Any (also temporary) stress in excess of the limiting values may cause permanent damage on CRep S10I and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.

Nominal Values

Parameter Minimal Typical Maximal Unit
Current consumption (running idle ) 130 mA
Current consumption (250k Bits/s, 100% bus load) tbd mA
Supply voltage 19 24 30 V
Propagation delay between two arbitrary channels 160 230 ns

All values, unless otherwise specified, refer to a supply voltage of 24V and an environmental temperature of 20°C.

Scope of Delivery

  • CRep S10I
  • User Manual

Related Products

CAN-Repeater CRep S4

CAN-Repeater CRep S8C

CAN Repeater CRep N

CAN Repeater CRep Opto

Further Information

CAN Repeater Example

CAN Repeater Networks

CAN Repeater Inhibit Time

International Sales

For US/Canada/Mexico sales, please contact: Traquair Data Systems, Inc. (www.traquair.com); sales@traquair.com; Ph: +1 607 266 6000