CAN/CAN Gateway CG-ARM7/GTI
is a railmountable CAN/CAN gateway, which transmits CAN signals between galvanic decoupled subsystems with differing data rates.
Special Features
CAN/CAN Gateway CG-ARM7/GTI
- Connection of CAN subnetworks with differing data rates
- Galvanic separation between the CAN channels
- Galvanic separation of the CAN channels to the power supply
- Filtering and buffering of data traffic
- Support of 11 bit and 29 bit identifiers
- Microcontroller NXP LPC2119 with two internal CAN controllers
- Version HS/LS with one transceiver PCA82C251 and one transceiver TJA1054
- Version LS/LS with two transceiver TJA1054
- Rail mountable
Description
The CAN/CAN gateway CG-ARM7/GTI transmits CAN signals between subsystems. CG-ARM7/GTI allows a flexible design of the wiring topology. Star and tree structures as well as extensive line structures can be realized. The galvanic separation between the CAN channels allows the use with diverging ground potentials.Among the available functions are data rate adaption, message filtering as well as identifier conversion between the coupled busses. The restriction of the maximum data rate depending on cable length for single CAN segments can be abolished for the over-all system by use of CG-ARM7/GTI.CG-ARM7/GTI obtains its potential through the use of a 32 bit microcontroller with 48 MHz clock. High speed processing and low latencies allow the use with high data rates and busloads. Cost efficient series applications are particularly promoted by use of CG-ARM7/GTI.The configuration of the device functions can take place either through CAN or through the built-in RS232 interface. Download software for the configuration is available for Windows PCs as well as Linux PCs and is within the scope of delivery.For special tasks, like modification of the data content of the CAN messages, we over a development kit to write custom specific firmware for CG-ARM7/GTI.Ordering information
Equipment / Variants
12-20-413-10
CG-ARM7/GTI
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Structural shape: Mounting rail
Protocol: CAN
12-20-416-10
CG-ARM7/GTI Version HS/LS
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high/low
Structural shape: Mounting rail
Protocol: CAN
12-20-417-10
CG-ARM7/GTI Version LS/LS
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: low speed
Protocol: CAN
Structural shape: Mounting rail
Technical Data
Layout and Connection
Both CAN busses are connected by a D-Sub9 male connector. Also the power supply and the RS232 interface have D-Sub9 male connectors.
Limiting Values
Parameter | Minimal | Maximal | Unit |
Storage temperature | -20 | +80 | °C |
Operating temperature | 0 | +60 | °C |
Supply voltage | -100 | +30 | V |
Voltage on bus connectors | -30 | +30 | V |
Admissible power consumption (at 60 °C) | n.s. | 2000 | mW |
Any (also temporary) stress in excess of the limiting values may cause permanent damage on CG-ARM7/GTI and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.
Nominal Values
Parameter | Minimal | Typical | Maximal | Unit |
Current consumption (running idle) | n.s. | 40 | n.s. | mA |
Supply voltage | 10 | 24 | 30 | V |
All values, unless otherwise specified, refer to a supply voltage of 24 V and an environmental temperature of 20 °C.
Scope of Delivery
- CAN/CAN gateway CG-ARM7/GTI
- User manual
- Configuration software
Related Products
Further Information
International Sales
For US/Canada/Mexico sales, please contact: Traquair Data Systems, Inc. (www.traquair.com); sales@traquair.com; Ph: +1 607 266 6000