CAN Repeater CRep Opto/M12
is a galvanic decoupling CAN repeater in a metal housing, which transmits and amplifies CAN signals in a protocol transparent way.
Special Features
CAN Repeater CRep Opto/M12
- Galvanic separation of CAN segments
- Protocol transparent, the CAN error handling is preserved
- Extended error suppression, separation of faulty segments
- Wide power supply range
- ISO 11898 compatible bus interface
- Assembly rail fixing, connection by M12 connectors
- Metal housing
Description
The galvanic decoupling CAN repeater CRep Opto/M12 transmits and amplifies CAN signals in a protocol transparent way. Both CAN connections behave like one single physical CAN node. CRep Opto/M12 allows the design of flexible wiring topologies. Star and tree structures as well as stub lines can be realized. By selection of the most favorable network topology for the application needs the installation costs can be lowered.The maximum data rate can be increased by use of CRep Opto/M12 and a suitable network structure. An increase in the number of nodes in a CAN network is possible through separation into sub networks, each of them connected by CRep Opto/M12. Each sub network can manage a maximum number of CAN nodes only restricted by the transceiver driver capabilities. With transmission over long distances CRep Opto/M12 allows signal recovering. Through the galvanic separation of the bus segments CAN sections with differing ground potential can be connected. For the most common occurring errors the integrated error suppression reduces the influence of faulty segments to intact sections.Ordering information
Equipment / Variants
12-02-112-20
CRep Opto-5/DS24/M12/RMD
For baud rate: 500 kB/s
For baud rate: 250 kB/s
Inhibit time: 500 ns
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CANopen
Structural shape: Mounting rail
Voltage supply: two-sided supplied
12-02-113-20
CRep Opto-10/DS24/M12/RMD
For baud rate: 125 kB/s
Inhibit time: 1000 ns
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CANopen
Structural shape: Mounting rail
Voltage supply: two-sided supplied
12-02-114-20
CRep Opto-20/DS24/M12/RMD
For baud rate: 50 kB/s
Inhibit time: 2000 ns
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CANopen
Structural shape: Mounting rail
Voltage supply: two-sided supplied
12-02-115-20
CRep Opto-50/DS24/M12/RMD
For baud rate: 20 kB/s
Inhibit time: 5000 ns
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CANopen
Structural shape: Mounting rail
Voltage supply: two-sided supplied
12-02-116-20
CRep Opto-100/DS24/M12/RMD
For baud rate: 10 kB/s
Inhibit time: 10000 ns
Galvanic separation: Host separated, Channels separated
Number of channels: 2 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CANopen
Structural shape: Mounting rail
Voltage supply: two-sided supplied
Technical Data
Layout and Connection
CRep Opto/M12 devices include 2 CAN Segments one fed to a male and one to a female plug of type M12. The plugs carry the CAN signals and the supply voltage. Each CAN segment needs its own power supply.
The following table shows the pinout of the M12 connectors.
Pin | Name | Function |
1 | SHLD | Shield connection |
2 | VCC | Positive power supply 24 V |
3 | GND | Ground |
4 | CAN_H | CAN signal line (dominant high) |
5 | CAN_L | CAN signal line (dominant low) |
Limiting Values
Parameter | Minimum | Maximum | Unit |
Storage temperature | -20 | +80 | °C |
Operating temperature | 0 | +60 | °C |
Supply voltage | -100 | +35 | V |
Voltage on bus connections | -30 | +30 | V |
Admissible power consumption (at 60 °C) | n.s. | 2000 | mW |
Any (also temporary) stress in excess of the limiting values may cause permanent damage on CRep Opto/M12 and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.
Nominal Values
Parameter | Minimum | Typical | Maximum | Unit |
Current consumption (running idle) | n.s. | 30 | n.s. | mA |
Current consumption (250 kBits/s, 100 % busload) | n.s. | 40 | n.s. | mA |
Supply voltage | 10 | 24 | 30 | V |
Propagation delay | n.s. | 125 | 200 | ns |
All values, unless otherwise specified, refer to a supply voltage of 24 V and an environmental temperature of 20 °C.
Scope of Delivery
- CAN repeater CRep Opto/M12
- User manual
Related Products
Further Information
International Sales