CAN Repeater CRep S26

CAN Repeater CRep S26

is a CAN Repeater with 26 CAN channels, which transmits and amplifies signals transparent to the CAN protocol.

Special Features

CAN Repeater CRep S26

  • Protocol transparent CAN repeater
  • 26 CAN channels
  • Low propagation delay
  • ISO 11898 compatible bus interface
  • Detach of dominant locked bus segments
  • Rail mountable

Description

The compact CAN repeater CRep S26 transmits and amplifies signals transparent to the CAN protocol. Each of the 26 CAN connections has the physical behavior of a single bus node. CRep S26 permits a flexible design of the network topology and offers special support for star structured networks. Furthermore tree structures and long stub lines are supported. Through the possibility to use the network structure that fits the application best a reduction of installation costs can be reached.The maximum data rate in CAN networks, depending on signal propagation delays, can be increased, if CRep S26 is used to improve the network structure. An increase of the maximum node count in a CAN network can be reached by splitting the network in subnets that are connected by CRep S26. Each subnet makes the number of CAN nodes possible permitted by the drivers output current. Where CAN signals have to be transmitted over long distances, CRep S26 can be used for signal conditioning. The capability to detach erroneous segments from the rest of the CAN system reduces the impact on the intact bus segments for the most commonly occurring errors.The presence of power is indicated by a LED. Furthermore each CAN channel is provided with a LED indicating that this channel has originated a CAN message when the LED is on.

Ordering information

Equipment / Variants

12-06-102-20

CRepS26­-05/S24/RMD

For baud rate: 500 kB/s

For baud rate: 250 kB/s

Inhibit time: 500 ns

Galvanic separation: None

Number of channels: 26 Channel

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-06-103-20

CRepS26­-10/S24/RMD

For baud rate: 125 kB/s

Inhibit time: 1000 ns

Galvanic separation: None

Number of channels: 26 Channel

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-06-104-10

CRepS26­-20/S24/RMD

For baud rate: 50 kB/s

Inhibit time: 2000 ns

Galvanic separation: None

Number of channels: 26 Channel

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-06-105-10

CRepS26­-50/S24/RMD

For baud rate: 20 kB/s

Inhibit time: 5000 ns

Galvanic separation: None

Number of channels: 26 Channel

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-06-106-10

CRepS26­-100/S24/RMD

For baud rate: 10 kB/s

Inhibit time: 10000 ns

Galvanic separation: None

Number of channels: 26 Channel

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

0

Technical Data

Layout and Connection

A CRep S26 device includes 26 CAN segments with male D-Sub9 connectors.

PinNameFunction
2CAN_LCAN low bus line
3GNDGround
7CAN_HCAN high bus line
1,4,5,6,8,9NCNot connected

The power supply of CRep S26 is galvanically separated from the CAN system and wired by a terminal block with 2 clamps.
The following table shows the terminal assignment of the power connector:

PinNameFunction
1Power +Positive supply +24 V
2Power –Ground of power supply

The power supply is galvanically decoupled from the CAN system.

Limiting Values

ParameterMinimumMaximumUnit
Storage temperature-40+80°C
Operating temperature0+60°C
Power supply voltage-100+35V
Voltage on signal lines-30+30V
Maximum power dissipation (at 60 °C)n.s.tbdmW

Any (also temporary) stress in excess of the limiting values may cause permanent damage on CRep S26 and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.

Nominal Values

ParameterMinimalTypicalMaximalUnit
Current consumption (running idle)n.s.100n.s.mA
Current consumption (250 kBits/s, 100 % busload)n.s.280n.s.mA
Supply voltage192430V
Propagation delay between 2 arbitrary channelsn.s.140180ns

All values, unless otherwise specified, refer to a supply voltage of 24 V and an environmental temperature of 20 °C.

Scope of Delivery

  • CAN repeater CRep S26
  • User manual

Related Products

CAN Repeater CRep S4

CAN Repeater CRep S8C

CAN Repeater CRep S10I

Further Information

CAN Repeater Example

CAN Repeater Networks

CAN Repeater Inhibit Time

International Sales

For US/Canada/Mexico sales, please contact: Traquair Data Systems, Inc. (www.traquair.com); sales@traquair.com; Ph: +1 607 266 6000