CAN Repeater CRep S4I/FD
is a CAN FD repeater with 4 channels, which transmits and amplifies signals transparent to the classic CAN or CAN FD protocol.
Special Features
CAN Repeater CRep S4I/FD
- Protocol transparent CAN repeater for CAN FD and CC
- 4 individually galvanically isolated CAN channels
- Galvanic separation between CAN channels to power supply
- Low propagation delay
- ISO 11898-2:2016 compatible bus interface
- Detach of dominant locked bus segments
- Rail mountable
- Optional with 120 Ohm or high impedance termination resistors
Description
The compact CAN repeater CRep S4I/FD transmits and amplifies signals transparent to the classic CAN and CAN FD protocol. Each of the four CAN connections has the physical behavior of a single bus node. CRep S4I/FD permits a flexible design of the network topology and offers special support for star structured networks. Furthermore tree structures and long stub lines are supported. Through the possibility to use the network structure that fits the application best a reduction of installation costs can be reached.The maximum data rate in CAN networks, depending on signal propagation delay, may be increased using CRep S4I/FD to improve the network structure. An increase of the maximum node count in a CAN network can be reached by splitting the network in subnets that are connected by CRep S4I/FD. Each subnet can have the maximum number of CAN nodes specified by the used CAN transceivers. Where CAN signals have to be transmitted over long distances, CRep S4I/FD can be used for signal conditioning. The capability to detach permanent dominant segments from the rest of the CAN system reduces the impact on intact bus segments for many often occurring errors. All CAN channels are galvanic separated to each other and to the power supply.The presence of power is indicated by a LED. Each CAN channel is provided with a LED indicating that this channel has originated a CAN message.Ordering information
Equipment / Variants
12-51-002-20
CRep S4I/FD-5/S24/RMD
For baud rate: 500 kB/s
For baud rate: 250 kB/s
Inhibit time: 500 ns
Termination: No Termination
Galvanic separation: Host separated, Channels separated
Number of channels: 4 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CAN FD
Structural shape: Mounting rail
12-51-102-20
CRep S4I/FD-5/S24/RMD
For baud rate: 500 kB/s
For baud rate: 250 kB/s
Inhibit time: 500 ns
Termination: 120 Ohm
Galvanic separation: Host separated, Channels separated
Number of channels: 4 Channel
CAN Physics: high speed
Protocol: CAN
Protocol: CAN FD
Structural shape: Mounting rail
Technical Data
Layout and Connection
A CRep S4I/FD device includes four CAN segments, wired by terminal blocks with 3 clamps. The power supply of CRep S4I/FD is separately wired by a terminal block with 2 clamps
Pin | Name | Function |
1 | CAN_H | CAN data line (dominant high) |
2 | CAN_L | CAN data line (dominant low) |
3 | GND | Ground |
The following table shows the terminal assignment of the power connector:
Pin | Name | Function |
1 | Power + | Positive supply +24 V |
2 | Power – | Ground |
The power supply is galvanicly decoupled from the CAN system.
Limiting Values
Parameter | Minimum | Maximum | Unit |
Storage temperature | -40 | +80 | °C |
Operating temperature | -20 | +70 | °C |
Power supply voltage | -100 | +35 | V |
Voltage on signal lines | -30 | +30 | V |
Maximum power dissipation (at 60 °C) | 0.s. | tbd | mW |
Any (also temporary) stress in excess of the limiting values may cause permanent damage on CRep S4I/FD and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.
Nominal Values
Parameter | Minimal | Typical | Maximal | Unit |
Current consumption (running idle) | n.s. | 120 | n.s. | mA |
Current consumption (250 kBits/s, 100 % busload) | n.s. | 260 | n.s. | mA |
Supply voltage | 10 | 24 | 30 | V |
Propagation delay between two arbitrary channels | n.s. | 150 | 230 | n.s. |