CAN Repeater CRep S8C

CAN Repeater CRep S8C

is a cascadable CAN repeater with 8 channels, which amplifies signals transparent to the CAN protocol.

Special Features

CAN Repeater CRep S8C

  • Protocol transparent CAN repeater
  • 8 CAN channels
  • Low propagation delay
  • Links for cascading up to 3 devices with one supply
  • ISO 11898 compatible bus interface
  • Detach of dominant locked bus segments
  • Rail mountable

Description

The compact CAN repeater CRep S8C transmits and amplifies signals transparent to the CAN protocol. Each of the eight CAN connections has the physical behavior of a single bus node. CRep S8C permits a flexible design of the network topology and offers special support for star structured networks. Furthermore tree structures and long stub lines are supported. Through the possibility to use the network structure that fits the application best a reduction of installation costs can be reached.The maximum data rate in CAN networks, depending on signal propagation delays, can be increased, if CRep S8C is used to improve the network structure. An increase of the maximum node count in a CAN network can be reached by splitting the network in subnets that are connected by CRep S8C. Each subnet makes the number of CAN nodes possible permitted by the drivers output current. Where CAN signals have to be transmitted over long distances, CRep S8C can be used for signal conditioning. The capability to detach erroneous segments from the rest of the CAN system reduces the impact on the intact bus segments for the most commonly occurring errors.The presence of power is indicated by a LED. Furthermore each CAN channel is provided with a LED indicating that this channel has originated a CAN message when the LED is on.

Ordering information

Equipment / Variants

12-04-102-10

CRep S8C-05/S24/RMD

For baud rate: 500 kB/s

For baud rate: 250 kB/s

Inhibit time: 500 ns

Galvanic separation: None

Number of channels: 8 Channel (cascadable)

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-04-103-10

CRep S8C-10/S24/RMD

For baud rate: 125 kB/s

Inhibit time: 1000 ns

Galvanic separation: None

Number of channels: 8 Channel (cascadable)

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-04-104-10

CRep S8C-20/S24/RMD

For baud rate: 50 kB/s

Inhibit time: 2000 ns

Galvanic separation: None

Number of channels: 8 Channel (cascadable)

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-04-105-10

CRep S8C-50/S24/RMD

For baud rate: 20 kB/s

Inhibit time: 5000 ns

Galvanic separation: None

Number of channels: 8 Channel (cascadable)

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

12-04-106-10

CRep S8C-100/S24/RMD

For baud rate: 10 kB/s

Inhibit time: 10000 ns

Galvanic separation: None

Number of channels: 8 Channel (cascadable)

CAN Physics: high speed

Protocol: CAN

Protocol: CANopen

Structural shape: Mounting rail

0

Technical Data

Layout and Connection

A CRep S8C device includes eight CAN segments, wired by terminal blocks with 3 clamps. The power supply of CRep S8C is separately wired by a terminal block with 2 clamps.

PinNameFunction
1CAN_HCAN high bus line
2CAN_LCAN low bus line
3GNDGround

The following table shows the terminal assignment of the power connector:

PinNameFunction
1Power +Positive supply +24 V
2Power –Ground

The power supply is galvanicly decoupled from the CAN system.

Limiting Values

ParameterMinimumMaximumUnit
Storage temperature-40+80°C
Operating temperature-20+60°C
Power supply voltage-100+35V
Voltage on signal lines-30+30V
Maximum power dissipation (at 60 °C)n.s.tbdmW

Any (also temporary) stress in excess of the limiting values may cause permanent damage on CRep S8C and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.

Nominal Values

ParameterMinimalTypicalMaximalUnit
Current consumption (running idle)n.s.70n.s.mA
Current consumption (250 kBits/s, 100 % busload)n.s.tbdn.s.mA
Supply voltage192430V
Propagation delay between two arbitrary channelsn.s.130200ns
Propagation delay cascaden.s.810ns

All values, unless otherwise specified, refer to a supply voltage of 24 V and an environmental temperature of 20 °C.

Scope of Delivery

  • CAN repeater CRep S8C
  • User manual

Related Products

CAN Repeater CRep S4

CAN Repeater CRep S10I

CAN Repeater CRep N

CAN Repeater CRep Opto

Further Information

CAN Repeater Example

CAN Repeater Networks

CAN Repeater Inhibit Time

International Sales