USB/CAN Interface CPC-USB/ARM7
is a CAN interface for USB ports with optional galvanic decoupling in a robust metal housing.
Special Features
USB/CAN Interface CPC-USB/ARM7
- Powerful Cortex M3 microcontroller with internal CAN and USB controller
- Supports CAN protocols 2.0A and 2.0B
- Display of USB communication and CAN data transfer via LEDs
- Supply completely over USB
- USB 2.0 Full Speed
- Optional with galvanic isolation between CAN and USB
- Optional with low speed transceiver TJA1054A
- Optional with ±80 V tolerant transceiver MAX13052
- Optional available with RJ45 CAN connector
- Linux socketCAN supported
- Free of charge development kits for Windows 7/8.x/10/11 and Linux
Description
CPC-USB/ARM7 is a CAN interface for USB ports in a compact and robust metal housing. Due to easy handling and favorable price CPC-USB/ARM7 is suitable for configuration and analysis of CAN systems.CPC-USB/ARM7 is equipped with a Cortex M3 microcontroller providing onChip CAN and USB controller. By combining the powerful CPU with internal peripherals low latencies can be achieved. The interface is completely supplied via USB, a separate supply for the CAN side is not needed.It supports 11 bit and 29 bit identifiers. The interface is optionally available with galvanic isolation. In addition also a variant with low speed transceiver TJA1054A is available. For applications, where a higher fault voltage on the CAN bus terminals cannot be avoided, the version HV is available. The use of the transceiver MAX13052 allows voltages up to ±80 V on the CAN bus lines. Also a version with RJ45 CAN connector is available.For the operating systems Windows and Linux software development kits with identical API are available free of charge. SocketCAN is supported.Ordering information
Equipment / Variants
10-08-401-10
CPC-USB/ARM7-GTI
Galvanic separation: Host separated, Channels common
Number of channels: 1 Channel
CAN Physics: high speed
Protocol: CAN
Structural shape: Other
10-08-400-10
CPC-USB/ARM7
Galvanic separation: None
Number of channels: 1 Channel
CAN Physics: high speed
Protocol: CAN
Structural shape: Other
10-08-403-10
CPC-USB/ARM7 Version LS
Galvanic separation: None
Number of channels: 1 Channel
CAN Physics: low speed
Protocol: CAN
Structural shape: Other
10-08-404-10
CPC-USB/ARM7-GTI Version LS
Galvanic separation: Host separated, Channels common
Number of channels: 1 Channel
CAN Physics: low speed
Protocol: CAN
Structural shape: Other
10-08-406-10
CPC-USB/ARM7-GTI Version HV
Galvanic separation: Host separated, Channels common
Galvanic separation: None
Number of channels: 1 Channel
CAN Physics: high speed - hv
Protocol: CAN
Structural shape: Other
Technical Data
Layout and Connection
CPC-USB/ARM7 includes a CAN segment connected by a male plug of type D-Sub9, the pin assignment is complying to CiA DS-102 for the standard version. In addition, the interface includes a USB connector that also carries the supply for CPC-USB/ARM7.
The following table shows the assignment of the CAN connector:
Pin | Name | Description Standard Version | Description Low Speed Version |
1 | RTL | Not connected | Connected with Pin 2 by a 5K6 resistor and with dedicated Pin of TJA1054 CAN transceiver |
2 | CAN_L | CAN bus line (dominant low) | CAN bus line (dominant low) |
3 | GND | CAN Ground | CAN Ground |
7 | CAN_H | CAN data line (dominant high) | CAN data line (dominant high) |
8 | RTH | Not connected | Connected with Pin 7 by a 5k6 resistor and with dedicated Pin of TJA1054 CAN transceiver |
4, 5, 6, 9 | – | Not connected | Not connected |
Limiting Values
Parameter | Minimal | Maximal | Unit |
Storage temperature | -20 | +80 | °C |
Operating temperature | 0 | +60 | °C |
Supply voltage | 0 | +6 | V |
Voltage on bus connections, standard version | -30 | +30 | V |
Voltage on bus connections, LS version | -27 | +30 | V |
Voltage on bus connections, HS version | -80 | +80 | V |
Any (also temporary) stress in excess of the limiting values may cause permanent damage on CPC-USB/ARM7 and other connected devices. Exposure to limiting conditions for extended periods may affect the reliability and shorten the life cycle of the device.
Nominal Values
Parameter | Minimal | Typical | Maximal | Unit |
Current consumption (idle mode) | n.s. | 100 | n.s. | mA |
Current consumption (operation mode) | n.s. | n.s. | 250 | mA |
Supply voltage | 4,0 | 5,0 | 5,5 | V |
All values, unless otherwise specified, refer to a supply voltage of 5 V and an environmental temperature of 20 °C.
Scope of Delivery
- USB/CAN interface CPC-USB/ARM7
- USB connection cable
- User manual
- proCANtool CAN‑Monitor for operating systems Windows 7/8.x/10/11
Related Products
USB/CAN FD Interface CPC-USB/FD
USB/CAN Interface CPC-USB/embedded
CAN Plug-In Board CPC-PCIe low profile
Further Information
CAN Bus USB Adapter for Crane Technics
International Sales
For US/Canada/Mexico sales, please contact: Traquair Data Systems, Inc. (www.traquair.com); sales@traquair.com; Ph: +1 607 266 6000